Local Reviews
for Lewis Center, OH
Excellent Service
Rebekah Moss - Lewis Center, OH 43035
We are very pleased with our service. Normally when you are given a window of time the attendant shows up at the end of the window, but Dave Atha was there right on time, and even could have been there earlier if we hadn't been working. It was an all around great experience. We would like to have Dave as our technician going forward.
Lewis CenterOH43035 40.22-83.0325Very thorough thanks Brad!
Allison - Lewis Center, OH 43035
Lewis CenterOH43035 40.1825-82.9725
Great Service
Shanelle - Lewis Center, OH 43035
Lewis CenterOH43035 40.1825-82.9725
Great service always
Nick - Lewis Center, OH 43035
Great service and workmanship every time! Thanks for all you do!
Lewis CenterOH43035 40.225-83
Response from Dor-Mar Heating & Air Conditioning:
Thank you for letting us earn your business, Nick! We appreciate you.
Great Service
Dushyant - Lewis Center, OH 43035
Lewis CenterOH43035 40.23-83.0325
Response from Dor-Mar Heating & Air Conditioning:
Thank you for the 5 star review, Dushyant! Dor-Mar appreciates your business.
David A.
Ac maintenance
Zach S.
Declined repai
David A.
Ac assessment
David A.
Plumbing Maintenance
David A.
Ac Maintenance
Skyler C.
I scheduled the customer's yearly plumbing and air conditioning maintenance.
Adam G.
NEED TO RETURN TO REPLACE THEINDUCER MOTOR FOR FURNACE AND REPLACE 15 FEET OF 12" FLEX DUCT. couldn't fit under the home would need to remove skirting and dig a crawl space.. also had snake issues under home inducer motor installed
Brandon M.
When I arrived, customer stated furnace was not heating her home. I created a call for heat. Inspected furnace operation found control board, showing fault code for igniter open tested igniter. And igniter red open jack igniter and found igniter shortage to ground notified customer and replace igniter furnaces now running and operating normal upon departure
Brandon M.
When I arrived customer stated his AC unit was not cooling his home. I created a call for cooling inspected condenser Operation. found furnace was running, The outside condenser was not. checked alcheck. The low voltage in had 0 V to contactor. And had 240 V high side Going to the contactor. checked furnace, found overflow to be tripped and open. found condensate Drain to be clogged. notified customer and cleared condensate. Drain line system is now running and operating normal upon departure. I would recommend having your ducts cleaned to help eliminate dust and dirt restricting the flow of condensation through the drain line and improve air quality and filter life expectancy.
Brandon M.
When I arrived tennett stated her AC was not working. I created a call for cooling inspected furnace condition and operation found lots of dirt debris built up throughout the blower motor and the blower wheel and throughout the inside of the furnace. checked evaporator coil. Found lots of rust, corrosion and potential spots leaking on evaporator coil. Checked outside condenser and performed amp. Draw on fan motor and compressor found compressor pulling Very high amps. indicating compressor is failing. Checked refrigerant pressure's, found that the system was completely empty of refrigerant, being the age condition and cost to temporarily repair I. Would strongly suggest replacement..